Call 08046030256 95% Response Rate

Send Email

Paperless Recorder

ANTHONE Paperless Recorders support universal input, including flow input, T.C, RTD, standard voltage, standard current, as well provide output control mode of PID, step-control(on -Off), auto-tuning, and manual operation etc.

Through connecting to micro-printer, the recorder can print the real-time/history data, and the trend curve which is appoint by user.

Through RS232 interface, the recorder can be connected to computer or PDA to upload the real and history data. With data processing software or U-disk tool software the data can be analyzed, stored, printed.

Through RS485 interface, the recorder can connect with professional configuration software, such as King-configuration, MCGS (monitor and controls generated system), to make up real time monitor system.     

Economical Series Paperless Recorder

Economical Series Paperless Recorder

Product Price: Rs 30,000 / Piece(s)Get Best Price

Product Details:
Usage/ApplicationIndustrial
ColorBlack
Power Consumption50 Watt
Voltage230 V
Country of OriginMade in India

Brief introduction
LU-R1000 paperless recorders may have 1 to 4 channels input, have outputs of on/off control, alarm, sensors power supply etc.

 

Technical parameters

· Outline dimension: 160*80mm

· Display: 128×64 high resolution chart blue LCD

· Input accuracy: ± (0.2%F.S+1) digit

· Input type:

Standard voltage: 0-5V, 1-5V

Standard current: 0-10mA, 4-20mA

T.C: K, S, B, T, E, J, Wre325, N

RTD: Pt100, Cu50, Cu100

Special input: R, Wre526, mV signal, other

(Indicate when ordering)

· Output type:

Switch signal output: Relay (resistance 250VAC/0.8A or 250VAC/3A)

SSR trigger (12V/50mA)

sensor power supply: DC12V/50mA

DC24V/50mA

DC5V/50mA

transform output: 4-20mA (load <650Ω), 1-5V

0-10mA (load <1000Ω), 0-5V

communication: RS232 or RS485

· Display mode:

Data, bar graph, real-time trend curve, history trend curve, alarm survey, alarm list.

· Storage: inner flash memory: 4MB (built in)

external storage: U-disk/2G (optional)

· Record: 4 pens without U disk, 5.8 days/4 pens (1 second interval) ~15 years/pen (4 minutes interval) with U disk/2G, 2×1024/4×[5.8 days/4 pens (1 second interval) ~15 years/pen (4 minutes interval)]

· Storage time:

T=storage capacity/ the sum of the reciprocal of each open channel’s record interval; when memory is empty, the storage capacity and the total storage is 4000×504.

For example: when the memory is empty, the open channels are 1, 3, 5, 7, the record interval of each channel is 1 second, 5 seconds, 10 seconds, 20seconds, then

T= 4000×504/(1/1+1/5+1/10+1/20)=1493333 seconds=414.8 hours=17.28days.

· Power off protection time: the data can be stored forever when the power is cut off because it adopts FLASH MEMORY, it can run accurately when power off because hard clock is equipped.

· Power: switch power supply 85VAC-264VAC, 50Hz±1Hz, power consumption is 8W;

· Ambient temperature: 0-45

· Ambient humidity: 0-85%RH



Additional Information:

  • Item Code: LU-R1000
Get Best QuoteRequest A Callback
Color LCD Paperless Chart Recorder

Color LCD Paperless Chart Recorder

Product Price: Rs 85,000 / PieceGet Best Price

Product Details:
Usage/ApplicationIndustrial
Parameter To Be MonitoredHumidity, Pressure, Temperature
Voltage24 V DC
Country of OriginMade in India

Brief introduction:

LU-R3000 color LCD recorders may have 1 to 16 channels input, have outputs of on/off control, alarm, sensors power supply etc.,

Technical parameters:

· Display window: 320×240 high resolution chart color LCD.

· Input accuracy: ± (0.2%F.S+1) digit.

· Input type:

standard voltage: 0-5V, 1-5V.

standard current: 0-10mA, 4-20mA

T.C: K, S, B, T, E, J, Wre325, N

RTD: Pt100, Cu50, Cu100

specially input: R, Wre526, mV signal, other (indicated when ordering)

· Output type:

Switch signal output: Relay (resistance 250VAC/0.8A or 250VAC/3A)

SSR trigger (12V/50mA)

Sensor power supply: DC12V/50mA, DC24V/50mA, DC5V/50mA

Transform output: 4-20mA (load <650Ω), 1-5V

0-10mA (load <1000Ω), 0-5V

Communication: RS232 or RS485

· Display mode: Enlarge data, all data, bar graph, real-time trend curve, history trend curve, alarm survey, alarm list.

· Storage: inner flash memory: 4MB (built in) external storage: U-disk/2G (optional)

· Record: 16 pens without U disk, 1.4days/16pens (1 second interval) ~15years/pen (4 minutes interval) with U disk/2G, 2×1024/4×[1.4days/16pens (1 second interval) ~15years/pen (4 minutes interval)]

· Storage time:

T=storage capacity/ the sum of the reciprocal of each open channel’s record interval; when memory is empty, the storage capacity and the total storage is 4000×504.

For example: when the memory is empty, the open channels are 1, 3, 5, 7, the record interval of each channel is 1 second, 5 seconds, 10 seconds, 20seconds, then

T= 4000×504/(1/1+1/5+1/10+1/20)=1493333 seconds=414.8 hours=17.28days.

· Power off protection time: the data can be stored forever when the power is cut off because it adopts FLASH MEMORY, it can run accurately when power off because hard clock is equipped.

· Power: switch power supply 85VAC-264VAC, 50Hz±1Hz, power consumption is 12W;

· Ambient temperature: 0-45

· Ambient humidity: 0-85%RH.



Additional Information:

  • Item Code: LU-R3000
Get Best QuoteRequest A Callback

EXPLORE MORE CATEGORIES

Contact Us
 
Thank youYour Enquiry has been sent successfully.